Overview:
The irrigationschedule
command displays the current watering schedule configured in your water management system. The schedule is presented in Tasmota format, an open-source firmware for ESP devices used to control your smart irrigation setup. It allows you to review the irrigation timers and settings without making any changes.
Command Structure:
irrigationschedule
Details:
- Upon entering this command, you’ll receive a detailed response outlining the current irrigation schedule, including specific times, durations for each watering session, and the designated days for irrigation.
- The irrigation schedule is controlled using Tasmota timers. Each timer manages different irrigation zones.
Timers:
Here’s how to interpret the timer information:
- Enable: Indicates if the timer is active (1 means enabled).
- Mode: Defines the timer mode (commonly 0 for time-based operation).
- Time: Specifies when the timer action will execute (in HH:MM format).
- Days: Indicates the days the timer runs ("1111111" means every day of the week).
- Repeat: If set to 1, the timer will repeat as scheduled.
- Output: Determines the device output that the timer controls (could represent different irrigation zones).
- Action: Indicates the action to take (1 for turning on, 0 for turning off).
Example Breakdown:
Timer1:
Time: 08:00
Action: 1 (Turn on)
Output: 1 (First irrigation zone)
Runs every day at 08:00.
Timer2:
Time: 08:05
Action: 0 (Turn off)
Output: 1 (Turns off the first irrigation zone).
Timer3:
Time: 08:05
Action: 1 (Turn on)
Output: 2 (Second irrigation zone)
Starts the second irrigation zone at 08:05.
Timer4:
Time: 08:10
Action: 0 (Turn off)
Output: 2 (Turns off the second irrigation zone).
Note: Timers 7 through 16 are set to 00:00, indicating that they may be unused or scheduled for future changes.
Time: 08:00
Action: 1 (Turn on)
Output: 1 (First irrigation zone)
Runs every day at 08:00.
Timer2:
Time: 08:05
Action: 0 (Turn off)
Output: 1 (Turns off the first irrigation zone).
Timer3:
Time: 08:05
Action: 1 (Turn on)
Output: 2 (Second irrigation zone)
Starts the second irrigation zone at 08:05.
Timer4:
Time: 08:10
Action: 0 (Turn off)
Output: 2 (Turns off the second irrigation zone).
Note: Timers 7 through 16 are set to 00:00, indicating that they may be unused or scheduled for future changes.
Summary of Schedule:
- Irrigation starts at 08:00 for zone 1 and turns off at 08:05.
- Zone 2 turns on at 08:05 and off at 08:10.
- Zone 3 turns on at 08:10 and off at 08:12.